Category: Trane cvhf chiller

Trane cvhf chiller

Serial L02C This is a secure server. Aaron does not sell or rent information to third parties. Please read our Privacy Policy for more information. View Privacy Policy. If you would like to be sent your password, please enter your email address below and press submit. We will send you an email with your password. We pay "Top Dollar" for your idle process equipment! Fill out our form and our buying team will get back to you. View our entire process equipment inventory online or visit our location for an equipment inspection.

Email or call us to speak with an equipment specialist to answer any machinery questions you may have. Stock Sign Into Your Account. If you have an account with us, login using your email address. Forgot Your Password? The login information you entered does not match our records. Do not have an account yet? Get started now! Please enter password. Account Benefits. View pricing online. Search our complete online inventory. Sign up for Equipment Alerts. Look up your quote history. Set up your personal profile.

List equipment directly on our site. Sell your surplus equipment. Thank You.Sincea Trane CenTraVac commercial chiller has led the industry as the most reliable, most efficient, lowest emission and quietest chiller in the world. For Technical Specifications, please refer to the Catalog or Installation documents on the Literature tab. If you are interested in CAD template drawings for Trane centrifugal chillers contact your local Trane sales office and work with a sales representative.

Fully configured drawings include application specific waterboxes and starters. Your sales representative can help you obtain the right unit selection and CAD file for your application. Trane is an equal opportunity and affirmative action employer. Privacy Policy. Overview Tech Specs Drawings Literature Sincea Trane CenTraVac commercial chiller has led the industry as the most reliable, most efficient, lowest emission and quietest chiller in the world.

Most Efficient - Selectable commercial chiller with full load efficiencies down to 0. Most Reliable - CenTraVac chillers have an average lifetime of 30 years and some have even lasted more than 50 years. CenTraVac Product Line. Related Equipment. Other Centrifugal Water-Cooled Chillers.Remember Me?

Page 1 of 2 1 2 Last Jump to page: Results 1 to 13 of Thread: trane cvhf centrifugal chiller sensor calibration. Thread Tools Show Printable Version. If its a UCP2 control, the differential between transducers can not be adjusted. I think can't remember the max diffential is 2 psid. Above that and the chiller will lock out.

trane cvhf chiller

I actually had one case where the transducers were fine, but the input on the board was bad and I had to replace the board. Easiest way to determine is swap inputs when chiller is off and make sure the readings cary over to the other input. Unually though one of the transducers is the problem. Don't overlook the oil filter or the fact that the sensors could be doing what they are suppose to, shut machine down to protect compressor. I've even had a few where the reason the pump assy was hard to turn was due to copper plating.

All my leon freaked out! When the diagnostic says "differential pressure transducer calibration" the UCP2 is trying to tell you the transducers are not reading equal when the machine is equalized. Any oil pump "drag" on a CVHF chiller will result in a blown fuse. You need to read my previous post which explains what to check. C'mon Scott, lighten up. Over the years, be it good or be it bad I've gotten in the habbit of keeping my options open.

After going through the original guestion a little more thoroughly I see now that my tangent was getting into a different subject. BTW, can you tell us how to calibrate the transducers? Just kidding!!!!Remember Me? Page 1 of 2 1 2 Last Jump to page: Results 1 to 13 of Thread Tools Show Printable Version. If someone tried to shortcut by skipping these two steps, and the replacement drier is swiftly swapped into place, how much refrigerant would be lost?

Is it significant? Is a special pump needed for steps 3 and 4? I'm concerned a typical vacuum pump might discharge too much oil. Originally Posted by ra. Why take a shortcut on this? Originally Posted by heavymetaldad.

Originally Posted by LGtonnagetech. RE-read step 2. Purge is already isolated Also, and especially in the case of HCFC, you want to eliminate as much of the refrigerant as practical from the waste product before removal.

Trane CVHE Installation, Operation And Maintenance Manual

Whadaya gonna save? Getting back to the original post questions. First, you most likely will have enough residual to set a quality, calibrated refrigerant monitor into alarm.

How much time do you think you're going to save taking shortcuts when you've got five to do? What kind of a vacuum pump do you use? Mine sure doesn't spew oil all over the place. The procedure cooolguy uses,is the same procedure I use. I will leave the gauge on for 1 or 2 hours, when I"m doing my maintenance. To make sure there is no leaks.

Join Date Aug Location Mixing oil and fire with a big spoon. Don't step on my favorite part of the Constitution just to point out your favorite part.

Trane CVHE Installation Manual

Here is a procedure I've used that is similar and works pretty wellPage of Go. Quick Links. See also: Installation Manual. Installation, Operation. Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and.

Improperly installed, adjusted or altered. When working on the equipment, observe all precautions in the. Table of Contents.

trane cvhf chiller

Trane Starters Engineering Bulletin 82 pages. Gear-driven centrifugal water-cooled liquid chillers with ch controls, cvgf ton units 50 and 60 hz 88 pages. Gear-driven centrifugal water-cooled liquid chillers, unit model cvgf ton units 50 and 60 hz 68 pages.

Water-cooled centravac chillers with tracer adaptiview control pages.

Trane CVHF 080

Water-cooled chillers with tracer adaptiview control pages. Air-cooled scroll chillers 20 - tons pages. Liquidchillers air-cooled scroll compressor 20 to tons 33 pages. Trane advocates the Page 6 Wiring Page 7 Sacrificial Anodes C—1 Waterbox Removal and Installation.

This system describes the product offerings using a product coding block which is made up of feature categories and codes that identify all characteristics of a unit.

Page Pre-installation 4. Check the oil sump sight glasses to verify that the actuate mechanical ventilation. Contractor shall provide Trane or an agent of Trane specifically authorized to perform start-up with notice of the scheduled start-up at least two weeks prior to the scheduled start-up. Page 13 If the chiller will be stored for more than six months after production, contact your local Trane Service Agency for required extended storage actions to minimize impact to the chiller and preserve the warranty.

Page Unit Components N N o o t t e e : : The control panel side of the unit is always designated as the front side of the unit. Suction Elbow 2. Compressor 3. Terminal Box 4. Control Panel 5. Condenser 6. Motor Housing 7. Economizer 8. Oil Tank Assembly 9. Purge Evaporator Figure 4. Clearance requirements Table 1.Also See for CVHE Engineering bulletin - 82 pages Installation, operation and maintenance manual - pages Installation, operation and maintenance manual - 89 pages.

Page of 28 Go. Typical evaporator water pipin Page 11 - Figure 4. Typical condenser water piping Page 12 - Figure 5. Typical CVHE grooved pipe conn Page 13 - Figure 6. Customer piping alternatives f Page 14 - Figure 7. Typical shipping location for Page 15 - Figure 8. Typical victaulic flange gaske Page 17 - Figure 10 - Bolt Tightening Sequences fo Page 21 - Figure Arrangement for rupture disc Page 23 - Figure Quick Links.

Installation —. Water Cooled CenTraVac. Required Installation Information:. Table of Contents. Trane Starters Engineering Bulletin 82 pages. Gear-driven centrifugal water-cooled liquid chillers with ch controls, cvgf ton units 50 and 60 hz 88 pages. Gear-driven centrifugal water-cooled liquid chillers, unit model cvgf ton units 50 and 60 hz 68 pages.

Water-cooled centravac chillers with tracer adaptiview control pages. Water-cooled chillers with tracer adaptiview control pages. Air-cooled scroll chillers 20 - tons pages. Liquidchillers air-cooled scroll compressor 20 to tons 33 pages.

Page 2: Warnings And Cautions — Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. All rights reserved. Follow ASME determine what water treatment, if c A heat-recovery condenser water guidelines or other applicable circuit, optional ; any, is required. Trane assumes no codes to assure proper relief responsibility for equipment failures valve installation.

Page 6: Figure 1. Flow Switch Installation Frequent cycling on these higher level diagnostic devices could cause excessive thermal and pressure cycling of unit components O-rings, gaskets, sensors, motors, controls, etc. Page 7: Evaporator And Condenser Water Piping Expenses that result from a failure to evaporator connections, arrange the follow this recommendation will not water piping so that the water supply be paid by Trane.

Page 8: Figure 2.Forums Forum list Search forums. What's new New posts New profile posts Latest activity.

trane cvhf chiller

Members Current visitors New profile posts Search profile posts. Log in Register. Search titles only. Search Advanced search…. Forum list. Search forums. Log in. We have a lot of fun, but make no mistake, we are pros. Hvacproforums is self supporting Do-it-yourselfers and Homeowners are encouraged to seek information elsewhere.

Those involved in the HVAC industry are urged to register. Slow Site? JavaScript is disabled. For a better experience, please enable JavaScript in your browser before proceeding. Trane CVHF oil pressure issue. Thread starter Seacurrent Start date Feb 16, Seacurrent Member. I am working on this chiller and when it is down I set the net oil pressure to 20 psi.

Then I checked it with the chiller off again and I have 30 psi. Anybody have any thoughts on this? Oil filter is new. Yes it has a regulator. I am not aware of a cleaning procedure. NZ All Blacks Fan said:. Oil pressure with the machine down? You mean with the machine off and the oil pump running? Sent from my iPhone using Tapatalk. Seacurrent said:. Actually, I didn't get back to the job until yesterday and the problem has mysteriously disappeared. So I'm gonna assume that maybe some small debris was interfering with the regulator.

I will keep an eye on it and hope that's the end of it. There are 3 chillers here and they only need to run 1 at any given time except on the hottest days of summer when occasionally another one will start so there is plenty of redundancy. You must log in or register to reply here.